Item no.: THP4200TN · EAN: 4251768800081


  • Temperature range -2°C / +8°C

  • Cooling chamber volume 550 liters

  • Energy efficiency class B

  • with 6 castors, 3 of which are braked

  • Shelf size: 325x530mm

  • Dimensions (WxDxH): 136x70x86cm


Skyrainbow recirculating cooling table, 4 doors with raised edge, -2°C to +8°C, 2230 x 700 x 960



The Skyrainbow recirculating air cooling table offers high and consistent quality standards directly from the manufacturer at an excellent price.



The Skyrainbow recirculating air cooling table is perfect for snack bars and shops for storing and selling chilled food and drinks,

as the temperature range from -2°C to +8°C can be set and controlled via the digital display according to your individual needs. The

Work surface offers sufficient space for your preparation equipment such as cutting boards, knives, and bowls.

The refrigerated interior offers sufficient space for storing fresh vegetables, various sauces, and other foods.

 

The use of the environmentally friendly refrigerant R290 ensures that our appliance has a long service life and is energy efficient.



Product features




  • environmentally friendly R290 refrigerant

  • Convection cooling system

  • Brand-name compressor

  • Dixell digital thermostat

  • with defrost heating for a shortened defrost phase (manual and automatic)



Product details




  • Interior/exterior stainless steel (galvanized rear wall)

  • Insulation 45 mm enables stable temperature and energy savings

  • self-closing door

  • Door seal washable and replaceable

  • with wheels (mounted), conversion to castors possible

  • particularly easy to clean thanks to rounded corners and edges

  • suitable for GN 1/1 containers (GN containers NOT included)

  • can be stacked

  • optional with drawers



Technical specifications




  • Climate class 4 (ambient temperature 30°C and room humidity 55%)

  • ready to plug in


Technical data

Dimensions (W × D × H)2230 × 700 × 960 mm
Weight148 kg
Voltage230V
Power430W
Current7.08A
Gross capacity (l)550
Net capacity (l)447
Temperature from-2°C
Temperature to+8°C
Cooling rangeRefrigeration
Cooling systemFan-assisted cooling
Climate classClimate class 4
RefrigerantR290
Refrigerant charge105g
DefrostingAutomatic defrost
Interior lightingNo
Insulation45mm
Exterior materialStainless steel
Interior materialStainless steel
WorktopStainless steel
UpstandWith upstand (stainless steel)
Depth (cm)70cm
Shelf sizeGastronorm (GN1/1)
Energy efficiency index (EEI)33
Energy class scaleA+++ – G
Energy consumption (kWh/year)976
Energy consumption (kWh/24 h)2.675
Packing unit1

Safety instructions

  • Do NOT use the device outdoors. For indoor use only.
  • DO NOT use devices that show signs of damage. If in doubt, consult a specialist.
  • DO NOT use mechanical devices or other means to accelerate the defrosting process.
  • DO NOT stand on or lean against the device or any part of it.
  • DO NOT place any loose objects, corrosive acids or alkalis, or liquids in the appliance.
  • Bottles containing a high alcohol content must be sealed and placed upright in the appliance.
  • Do NOT use this appliance to store medical equipment.
  • Do NOT place in an area where a water jet could be used.
  • DO NOT use jet/pressure cleaners to clean the device.
  • Always transport, store, and handle the device in an upright position and move it by holding the base of the device.

Warning

  • This cooling/freezing chamber must be properly installed by a qualified technician and set up according to the installation instructions
  • Switch off the appliance and disconnect the power plug before repairing or cleaning it.
  • NOTE: Repairs must be carried out by a qualified technician.
  • Remove all packaging cartons, bags, foils, and pallets before use.
  • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Do not place any flammable or explosive substances, such as spray cans with flammable propellants, in this device.
  • Dispose of the packaging in accordance with local regulations.
  • The device is intended for commercial use and similar applications and may only be operated by trained personnel.
  • Do not use harsh cleaning agents on the device.

Explosion hazard

This device contains isobutane refrigerant, R290 or R600a, a natural gas with high environmental compatibility. However, it is flammable. Observe the following warnings to avoid the risk of injury or damage to property.

  • To prevent the formation of a flammable gas-air mixture due to a leak in the refrigerant circuit, the size of the room in which the appliance is installed depends on the amount of refrigerant used. The amount of refrigerant in your appliance is indicated on the type plate inside the housing.
  • When handling, installing, and operating the device, make sure that the refrigerant lines are not damaged.
  • Maintenance must only be carried out by authorized service personnel. Use only service parts approved by the manufacturer.
  • Keep the ventilation openings in the appliance housing free of obstructions.
  • Do not use any electrical appliances inside the food storage compartment of the appliance (e.g., heating devices, ice machines, etc.).

power connection

  • Connect the appliance to a grounded 3-pole socket.
  • Do not use an adapter
  • Do not use an extension cord.
  • The power cord of this appliance is equipped with a three-prong (grounded) plug that can be connected to a standard three-prong (grounded) outlet.
  • The device should always be connected to its own power outlet with a voltage that matches the voltage specified on the type plate.
  • A 230 volt AC, 50 Hz, grounded power supply is required. This provides the best performance and prevents overloading of the house's electrical circuits, which could lead to a fire hazard due to overheated wires.
  • Never pull the plug of your device out of the socket by pulling on the power cord.
  • Do not operate the device if the power cord is defective.
  • When moving the device away from the wall, make sure that you do not damage the power cord.