Blast chiller, 3x GN2/3, black lacquered | Skyrainbow TSD40B

Skyrainbow

Item no.: TSD40B · EAN: 4251768810424


  • suitable for 3x GN2/3 H=65mm

  • Color black

  • Refrigerant R290

  • Capacity 40L

  • Dimensions (WxDxH) 741 x 700 x 470mm


Skyrainbow convection blast chiller and blast freezer 3x GN2/3



The Skyrainbow blast chiller and blast freezer is the ideal addition to your kitchen. Thanks to the fast

Cooling process, the product quality of the food remains high and possible germ contamination is reduced.

One of the most important components for efficiently increasing the shelf life of food. Perfect for producing

of your own convenience products. At the end of the blast chilling process, the appliance automatically switches to

Hold and then behaves like a normal refrigerator or freezer to save energy

allows it to be used even in the smallest of kitchens.





Product features




  • Use with refrigerant R290

  • Circulating air cooling system

  • Brand compressor

  • Dixell digital thermostat

  • with core temperature sensor



Product details




  • Stainless steel interior

  • Black painted exterior (galvanized back wall)

  • Insulation 60 mm

  • with lighting

  • with self-closing door (door hinges on the right cannot be changed)

  • particularly easy to clean thanks to rounded corners and edges

  • automatic defrosting in hold phase

  • with core temperature sensor

  • Blast chilling capacity: 9kg from +65°C to +3°C in 90 minutes

  • Blast freezing capacity: 6kg from +65°C to -18°C in 240 minutes

  • 3 shelves for 2/3GN H=65mm



Technical specifications




  • Climate class 4 (ambient temperature 30°C and room humidity 55%)

  • max. cooling capacity: 960W

  • Evaporator temperature rapid cooling: -20°C

  • Evaporator temperature shock freezing: -35°C

  • Ready to plug in


Technical data

Dimensions (W × D × H)741 × 700 × 470 mm
Weight82 kg
Voltage230V
Power936W
Current4.2 A
Temperature from+10°C
Temperature to-30°C
Cooling rangeRefrigeration | Freezing
Cooling systemFan-assisted cooling
RefrigerantR290
Refrigerant charge76 g
DefrostingAutomatic defrost
Interior lightingYes
Insulation60mm
Exterior materialBlack painted
Interior materialAISI 201
Door typeSolid door
Door hingeRight
Reversible doorNo
LockableNo
Built-in capableNo
Shelf sizeGastronorm (GN2/3)
Packing unit1

Safety instructions

  • DO NOT use the appliance outdoors. For indoor use only.
  • DO NOT use appliances that show signs of damage. If in doubt, consult a specialist.
  • DO NOT use mechanical devices or other means to speed up the defrosting process.
  • DO NOT stand or lean on the appliance or any part of it.
  • DO NOT place volatile objects, corrosive acids or alkalis or liquids in the appliance.
  • Bottles containing a high percentage of alcohol must be sealed and placed vertically in the appliance.
  • DO NOT use this appliance to store medical supplies.
  • DO NOT place in an area where a water jet could be used.
  • DO NOT use jet/pressure washers to clean the appliance.
  • Always transport, store and handle the appliance in a vertical position and move it by holding the base of the appliance.

Warning

  • This refrigerator/freezer must be properly installed by a qualified technician and set up according to the installation instructions
  • Switch off and unplug the appliance before repairing or cleaning it.
  • NOTE: Repairs must be carried out by a qualified technician.
  • Remove all packaging boxes, bags, foils and pallets before commissioning.
  • Do not store or use gasoline or other flammable vapors and liquids near this or any other appliance.
  • Do not place flammable, explosive substances such as spray cans with flammable propellants in this appliance.
  • Dispose of the packaging in accordance with the regulations of the local authorities.
  • The appliance is intended for commercial use and similar applications and may only be operated by trained personnel.
  • Do not use harsh cleaning agents on the appliance.

Explosion hazard

This appliance contains isobutane refrigerant, R290 or R600a, a natural gas with high environmental compatibility. However, it is flammable. Observe the following warnings to avoid the risk of injury or damage to property.

  • To prevent the formation of a flammable gas-air mixture due to a leaking refrigerant circuit, the size of the room in which the appliance is installed depends on the amount of refrigerant used. The refrigerant quantity of your appliance is indicated on the rating plate inside the housing.
  • When handling, installing and operating the appliance, ensure that the refrigerant lines are not damaged.
  • Maintenance may only be carried out by authorized service personnel. Only use service parts approved by the manufacturer.
  • Keep the ventilation openings in the appliance housing free of obstructions.
  • Do not use any electrical appliances inside the food storage compartment of the appliance (e.g. heaters, ice machines, etc.).

power connection

  • Connect the device to an earthed 3-pin socket.
  • Do not use an adapter
  • Do not use an extension cord.
  • The power cord of this appliance is fitted with a three-pin (earthed) plug which can be connected to a standard three-pin (earthed) socket outlet.
  • The appliance should always be connected to a separate socket outlet with the same voltage as indicated on the rating plate.
  • A 230 volt AC, 50 Hz, earthed power supply is required. This provides the best performance and prevents overloading the house circuits, which could result in a fire hazard due to overheated wires.
  • Never unplug your appliance by pulling on the power cord.
  • The appliance must not be operated if the mains cable is defective.
  • If you move the appliance away from the wall, make sure that you do not damage the power cable.
Cancel contract